logo

当前位置:首页 / Products / Voltage probe

DPR6000A Series

DPR6000A Series High-Voltage Differential Probe

The DPR6000A series high-voltage differential probes are high-voltage differential probes with floating measurement capability. Their maximum bandwidth reaches 100MHz, meeting the needs of most test systems. The probes are equipped with RS232 serial communication function. When used with our company's intelligent probe controller OT7052, customers can read the probe status, control the probe to switch ranges, bandwidth, and overload mute function through the intelligent probe server on the PC. OT7052 effectively solves the problem of power supply and communication control for up to 52 intelligent probes in automatic test systems. The DPR6000A series offers a variety of ranges, and their differential measurement voltage range meets the requirements of most test circuits. If the probe becomes offset after long-term use, users can enter the test mode to adjust the bias and achieve zeroing. Electronic touch buttons extend the service life. It has a 5MHz bandwidth limit function option; the 5MHz frequency bandwidth meets the measurement requirements of FETs' switching frequency in most switching power supplies and can filter out higher-frequency noise and interference. It is equipped with sound and light alarm functions, and the sound alarm can be manually turned off, featuring a more user-friendly design.

主要特点
应用领域
  • New Energy Vehicles.webp

    New Energy Vehicles

  • Industrial Automation and Control.webp

    Industrial Automation

  • Power Electronics.webp

    Power Electronics

  • Scientific Research Experiments.webp

    Scientific Research Experiments

产品规格

Electrical Specifications

ModelDPR6070ADPR6150ADPR6350ADPR6700A
Bandwidth (-3dB)100MHz
Rise Time≤3.5ns
Accuracy±2%
Range Selection (Attenuation Ratio)10X/100X50X/500X100X/1000X100X/1000X
Maximum Differential Measurement Voltage Vp
(DC + Peak AC)
10X±70V50X
±150V100X
±350V100X
±700V
100X±700V500X±1500V1000X±3500V1000X±7000V

Common Mode Voltage (DC + Peak AC)±700V±1500V±3500V±7000V
Maximum Differential Mode Voltage vs. Frequency CurveRefer to Figure 1Refer to Figure 2Refer to Figure 3Refer to Figure 4
Maximum Input Voltage to Ground (Vrms)450V CATII
600V CATI*
600V CATIII
1000V CATII
600V CATIII
1000V CATII
1000V CATIII
2300V CATI*
Input ImpedanceSingle-ended to Ground2.5MΩ5MΩ5MΩ20MΩ
Between Two Input Terminals5MΩ10MΩ10MΩ40MΩ
Input CapacitanceSingle-ended to Ground<4pF<4pF<4pF<5pF
Between Two Input Terminals<2pF<2pF<2pF<2.5pF
CMRRDC>80dB>80dB>80dB>80dB
100kHz>60dB>60dB>60dB>60dB
1MHz>50dB>50dB>50dB>50dB
Noise (Vrms)10X<25mV50X<50mV100X<100mV100X<220mV
100X<120mV500X<300mV1000X<600mV1000X<1.2V
Overload Indication Voltage Threshold10X≥70V50X≥150V100X≥350V100X≥700V
100X≥700V500X≥1500V1000X≥3500V1000X≥7000V
Input ImpedanceProbe Main Unit10X8.7ns50X8.5ns100X8.2ns100X8.9ns
100X8.1ns500X7.5ns1000X7.4ns1000X6.6ns
BNC Cable (1m)5ns
Bandwidth Limit (5MHz)≥-3dB@5MHz
Overload Indicator Light (Red)Yes
Overload Alarm SoundYes (Can be turned off optionally)
Auto-save FunctionYes
Adjustable Bias FunctionYes (Adjustable in test mode)
Termination Load Requirement≥100kΩ
Power Supply MethodOT7052
Safety Compliance StandardEN61010-1: 2010
EMC Compliance StandardEN61326-1:2013    EN61000-3-2:2006+A1:2009+A2:2009    EN61000-3-3:2013


资料下载

寻找更多销售、技术和解决方案的信息?

联系我们
联系电话: 020-2204 2442
邮箱:Sales@greentest.com.cn
微信客服二维码
Baidu
map